Seat Test, 40 Inch Gate Valve,cast Steel, API 600, Flexible Wedge,

1661913235216


The procedure of gate valve sealing test.


1. Mounting position of the valve - the axes of the main branch pipes are parallel to the floor surface.

2. The direction of supply of the test medium is two-sided. The test medium is supplied in turn to each branch pipe, and the leakage through the gate is controlled from the opposite branch pipe of the gate valve at atmospheric pressure.

3. Before starting the test, it is necessary to run two "open-closed" cycles without supplying the test medium. The movement of moving parts must be smooth without jerking or jamming.

4. When moving the wedge to close and open, the force on the handwheel required to move the wedge from one extreme position to another should be measured. The force is measured by a dynamometer. Control of the extreme positions of the WEDGE by the position indicator.

5. Valve tests are carried out with water at a pressure of 1.1 Pp (17.6 MPa) and with air at a pressure of (0.6 ± 0.05) MPa. Test medium temperature (20±15) °С.

6. When testing, lubrication of the sealing surfaces of the valve is not allowed.

7. Control method:

 - when tested with air - by diverting leakage from the cavity of the valve through a tube immersed in a container with water into a measuring container.

- when tested with water - hydrostatic, by diverting leakage from the cavity of the valve into a measuring container (calibrated pipette).

8. Exposure of the product at a steady pressure before the start of leak testing and leakage control time in accordance with the table

9.Gate leakage measurement should be performed at least three times. When repeating the test, the shutter is moved to a full stroke after each measurement.

10. Water test sequence.

10.1 The test procedure takes into account the change in the coefficient of thermal expansion of water with a change in its temperature.

10.2 A leak indicator should be used for monitoring. The leak indicator is connected to the fitting of the plug installed on the outlet of the product. During the test, the leak indicator must be above the level of the product seal.

10.3 - measurement of leakage at test pressure should be repeated at least three times, each time before holding the product under pressure, one “closed-open-closed” cycle should be run. The holding time is 300 seconds;

10.4 - measure and fix the water leakage (Q1 Ratm) at a pressure equal to atmospheric Psp1=Ratm;

10.5 - measure and fix water leakage (Q2 Р=17.6 MPa) at pressure Р test2=1.1 Рр (17.6 MPa);

- in the branch pipes and the body of the product, relieve the pressure to atmospheric;

- disconnect the pipeline supplying the test medium;

- withstand the product without pressure for 10 minutes;

- measure and fix water leakage (Q3 Ratm) at a pressure equal to atmospheric pressure Psp3=Ratm;

- calculate the arithmetic mean of leakage at a pressure equal to atmospheric, according to the formula QPatm=(Q1 Ratm+Q3 Ratm)/

10.6 If gate leakage QP=17.6 exceeds QPatm leakage, then the actual gate leakage should be taken as the value equal to the difference between the measured leaks: Qact = QР=17.6 - QPatm.

10.7 If the leaks in the valve QР=17.6 do not exceed the leakage QРatm (QР=17.6 ≤ QР=atm), then it should be considered that the leakage in the valve of the product is equal to zero and the tightness of the valve of the product corresponds to the tightness class "A" according to ISO 5208.

10.8 Evaluation criteria - no leaks in the valve - valve tightness class "A" according to ISO 5208 - no visible leaks during the test period.

In the process of visual control, the following are not rejection signs:

a) when tested with water - the formation of dew, which does not turn into dripping drops, along the contour of the sealing surface;

b) when tested with air - the formation of bubbles that do not detach or burst;

c) when used to measure the leakage of technical means:

1) when tested with water - leakage in the valve Q≤9.010-4 cm3/min;

2) when tested with air - leakage in the valve Q≤3.010-3 cm3/min.


Name

Big dimension gate valve

Type

OS&Y, Full bore, flexible wedge

Nominal Size

40 inch

Nominal pressure

150lb

Media

hot air

Working Temp.

350 C

Body

WCB

Wedge

WCB+STL

Seat

STL

Stem

ASTM A182 F6a

Bolts/nuts

B7/2H

Operation

Gear operated

Design

ASME B16.34,API 600

Face to face

ASME B16.10

End

ASME B16.5

Test

API 598, ISO 5208

Delivery

50 days

Painting

Expoxy

Packing

Plywood Case

MOQ

1 Set

Certificate

ISO9001, ISO14001,ISO45001,  SIL, API 6D,CE

Origin

Wenzhou, China (Mainland)

Project

Malaysia