The operation of the check valve should avoid the following situations:
1) Excessively high shock pressure caused by the closing of the check valve.
2) The valve closing part quickly oscillates.
In order to avoid the excessively high shock pressure caused by closing the check valve, the valve must be closed quickly to prevent the formation of a great backflow velocity. The reverse flow speed is the cause of the impact pressure, so the closing speed of the check valve should be correctly matched with the decay speed of the downstream medium.
However, the decay rate of downstream media may vary greatly in liquid systems. For example, if a group of parallel pumps are used in a liquid system, and one of them suddenly fails, the check valve at the outlet of the failed pump must be closed almost at the same time. In addition, if there is only one pump in the liquid system, and the pump suddenly fails, if the delivery pipe is longer, and the back pressure and pumping head at the outlet end are lower, it is better to close the check valve with a lower speed.
If the moving parts of the check valve wear out too quickly, it will cause the valve to fail prematurely. In order to prevent this from happening, it is necessary to avoid rapid oscillation of the closure member. This rapid oscillating action of the closing member can be avoided by selecting a valve for a medium speed that forces the closing member to stably deal with the stop of the flow of the medium.
This ideal situation is not always available. For example: If the velocity of the downstream medium varies widely, the minimum flow velocity is not enough to force the closing member to stop stably. In this case, the movement of the closing member can be restrained by a damper within a certain range of its movement stroke. If the medium is a pulsating flow, the check valve should be placed as far away as possible from the source of pulsation. The rapid oscillation of the closing member may also be caused by extreme media disturbance. Where this situation exists, the check valve should be placed where the media disturbance is minimal.
Therefore, selecting a check valve is first to grasp the working conditions of the check valve.